Sequentia lineamenta describunt hanc salutem intrinsecam fluctui praeventioni fabrica pro 24 systematibus volt;
12.4 mm consilio tenuissimo consilio incredibile spatium efficax est, faciens illud specimen pro locationibus cubiculi limitatis. Simplex quoque est ut in scriniis vel aliis instrumentis moderandis instituatur.
Quia impetus moduli aestus in swappable calidus est, operans salutem et commoditatem augetur, quia ratio non opus est claudere sustentationem vel moduli tutelam reponens.
Unius usus deprehensio: Salvus tutelae modulus independenter probatus esse potest, qui promptam identitatem et resolutionem exituum adiuvat et systematis operationem continuam praestat.
Amplis ambitus signorum applicabilis: tutelam efficientem praebet pro amplis circuitionibus signorum, incluso RS232, DI, DO, AO, AI (analog input, digital output).
DIN35 ductore metallico utens fundamento rail: augere stabilitatem et salutem systematis possibilis est fundare per ductor metallicus rail, quod firmitatem instrumentorum fundationis praestat.
SPECIFICATIONS
Technical data | Duo-filum | Tres-filum | Quattuor filum |
Rated voltage Un operating | 24V | 24V | 24V |
Maxime voltage Uc operating | 32V | 32V | 32V |
Nominal operating current II | 600mA | 600mA | 600mA |
Nominalis missio currentis in (8 / 20μs) | 10kA | 10kA | 10kA |
Maxime vena missionis (8 / 20μs) | 20kA | 20kA | 20kA |
Flumen claudicationis fulmen fluctus (10 / 350μs) | 2.5kA | 2.5kA | 2.5kA |
Totalis fulguris impetus current (10 / 350μs) | 5 kA | 7.5kA | 10kA |
Praesidium voltage Sursum (8 / 20μs) linea ad lineam / lineam ad terram | 60V/600V | 60V/600V | 60V/600V |
Praesidium voltage Sursum (1KV / μs) linea ad lineam / lineam ad terram | 40V/600V | 40V/600V | 40V/600V |
Sed in (-0.5dB) | 10MHz | 10MHz | 10MHz |
Responsio tempus | 1ns | 1ns | 1ns |
Series resistentia (per lineam) | 1Ω | 1Ω | 1Ω |
Lacus current | 10μA | 10μA | 10μA |
Gradus tutelae clausurae provisae (linea IEC 60529) | IP 20 | IP 20 | IP 20 |
Materia habitationi / flamma retardant gradus (UL94) | PC/V0 | PC/V0 | PC/V0 |
Test vexillum | GB/T 18802.21/IEC61643-21 | GB/T 18802.21/IEC61643-21 | GB/T 18802.21/IEC61643-21 |
CREPITUS certificationes | EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga | EX ia II C T4-T6 Ga |
Opus temperatus range | -40 ~ +80 | -40 ~ +80 | -40 ~ +80 |