Isishwankathelo
Igalelo lokumelana ne-Thermal Izithintelo zokhuseleko ezizimeleyo zinokusasaza i-thermal resistor (RTD) Pt100 ye-two-wire okanye i-3-wire kwindawo eyingozi kwindawo ekhuselekileyo 1:1.
Le mveliso ifuna unikezelo lwamandla oluzimeleyo, kunye nonikezelo lwamandla olulodwa, igalelo, kunye neetheminali eziphumayo.
Iinkcukacha
Igalelo kwindawo eyingozi | |
Uphawu longeniso | Iingcingo ezimbini okanye ezintathu Pt100 uphawu |
Uluhlu lomlinganiselo | -200℃-850℃ |
Imveliso yecala lokhuseleko: | |
Umqondiso wemveliso | RTD PT100 uphawu |
Uchulumanco lwangoku | 0.1-3mA |
Unikezelo lombane | 20-35VDC |
Ukutya umbane | ≤40mA (xa 24VDC unikezelo lwamandla) |
Isalathisi se-LED | Luhlaza: Isalathisi samandla I-alam yoluhlu oluphantsi isibane esityheli silayitiwe, isibane esibomvu soluhlu oluphezulu sivuliwe |
Ukuchaneka kwemveliso | 0.1%FS |
Ukukhukuliseka kobushushu | 0.1%FS/℃ |
Iiparamitha zobushushu | Ubushushu bokusebenza: -20℃~+60℃, ubushushu bokugcina:-40 ℃~+80℃ |
Ubuntu bezizalwane | 10% ~ 95% RH akukho condensation |
Amandla e-Dielectric | Phakathi kwecala elikhuselekileyo langaphakathi kunye necala elingakhuselekanga (≥ 3000VAC / min); phakathi konikezelo lwamandla kunye netheminali engeyoyangaphakathi ekhuselekileyo (≥ 1500VAC/min) |
Ukumelana ne-insulation | ≥100MΩ (phakathi kwegalelo/imveliso/ubonelelo lwamandla) |
Ukuhambelana kwe-electromagnetic | Ngokutsho kwe-IEC 61326-1(GB/T 18268), IEC 61326-3-1 |
MTBF | 100000h |
Iimfuno zocingo | Umphezulu wokusika othe tye ≥ 0.5mm2; Amandla e-Insulation ≥ 500V |
Izixhobo zentsimi ezisebenzayo | Iingcingo ezimbini okanye ezintathu RTD Pt100 |
Indawo yofakelo | Ifakwe kwindawo ekhuselekileyo, inokuxhunywa kwizixhobo zokhuseleko lwangaphakathi kwiindawo ezinobungozi ukuya kwi-Zone 0, IIC, Zone 20, kunye ne-IIIC. |
Izatifikethi ezikhuselekileyo ngokwangaphakathi | |
Uphawu lobungqina bokudubula | [Eks ia Ga]lIC [Ex ia Da]lllC |
Umgangatho wobungqina bokudubula | GB/T3836.1-2021 GB/T3836.4-2021 |
Izikhululo ze-3-2, 4-2 | Um:250V AC/DC Uo=8.4V DC lo=31mA Po=65.1mW Co=4.8µF Lo=20mH |
Iqumrhu lezatifiketi | I-CQST(iZiko leSizwe lokuJonga uMgangatho kunye neZiko loVavanyo lokuPhuma kweeMveliso zoMbane eziKhuselweyo) |
Ubungakanani
Umzobo wocingo
Phawula:
1. Umsebenzi kaloliwe wamandla ngumsebenzi ozikhethelayo, kwaye abasebenzisi kufuneka bachaze indlela yonikezelo lwamandla xa bebeka umyalelo.
Ukukhethwa kweziqhagamshelo zikaloliwe zamandla kunokubhekisa kwiphepha lama-89 le "Isihlomelo"
2. Xa ufaka i-RTD yocingo oluthathu, kuyimfuneko ukuqinisekisa ukuba iingcingo ezintathu zinobude obulinganayo kangangoko kunokwenzeka.
3. Xa ufaka i-RTD yeentambo ezimbini, i-terminals barrier barrier terminals 4 kunye ne-2 kufuneka ibe yifutshane.