PHD-11TC-22

Communication Input

Products Categories
Featured Products

PHD-11TC-22

PHD-11TC-22

RS485 full-duplex input /RS485 full-duplex output

1 input 1 output


Overview

Isolated safety barrier at detection end: PHD-11TC-22, communication signal input, single input and single output.

    Product advantages

    The safety barrier can realize the bilateral communication of full duplex digital signals between RS485 interface in dangerous area and RS485 interface in safe area.
    This product needs an external 20-35VDC power supply.
    The product is equipped with signal status indicator (yellow).
    * bus terminal power supply, please see appendix for details.

    Specifications

    Specifications

     

    Supply voltage

    20~35VDC, power consumption about 1.5W  

    Input signal

    RS485 full-duplex digital signal

    Output signal

    RS485 full-duplex digital signal

    Number of input and output channels

    1 input 1 output

    Applicable field equipments

    Equipment with RS485 full-duplex communication interface

    Transmission rate

    Transmission rate ≤115.2kbps

    Transmission delay

    ≤10 μs

    Sending and receiving switching time

    ≥20ms

    Temperature parameters

    Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃

    Relative humidity

    10%~95% RH no condensation

    Relative humidity

    10%~95% RH no condensation

    Insulation resistance

    ≥100MΩ (between input/output/power supply)

    External dimensions

    Thickness 12.5mm x width 108mm x high 118mm

    Electromagnetic compatibility

    According to IEC 61326-1(GB/T 18268), IEC 61326-3-1

    Explosion-proof mark

    [Exia Ga]IIC

    Certification Body

    CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)

    Authentication parameters (between terminals 1-2-3-4)

    Um=250V  Uo=7.7V  Io=80mA  Co=6.9μF  Lo=5mH  Po=0.15W

    Installation site Requirements

    It can be connected with instruments in 0 zone with ⅡA, ⅡB, ⅡC dangerous gas

    MTBF

    About 100000h

    Wiring diagram

    phd11tc22zp0
    Terminal assignments and dimensions

    Terminal

    Terminal assignments

    9

    Power supply +

    2035VDC

    10

    Power supply -

    3

    Intrinsically safe side RS485-A

    4

    Intrinsically safe side RS232-B

    1

    Intrinsically safe side RS232-Y

    2

    Intrinsically safe side RS232-Z

    5

    RS485-A

    6

    RS485-B

    7

    RS485-Y

    8

    RS485-Z

    phd11tc22-16aj

    Application scenario

    ✯ Data transmission security: Through safety barriers, bidirectional digital signal communication can be carried out between hazardous and safe areas to ensure the secure transmission of data and prevent data from being tampered with or stolen.
    ✯ Remote monitoring and control: Remote device monitoring and control can be achieved through RS232 interface, such as remote data collection, remote device control, and other applications.
    ✯ Industrial automation: In industrial control systems, safety barriers can be used to connect equipment in different areas, achieve data exchange and control command transmission, and improve the automation and intelligence level of production lines.

    product display

    • Isolated Safety Barrier at Detection Side (1)317
    • Isolated Safety Barrier at Detection Side (5)uli