Get Instant Quote
Leave Your Message
PHD-11TC-33M

Communication Input

Products Categories
Featured Products

PHD-11TC-33M

Communication signal input isolated safety barrier 1 input 1 output

RS-485 Half Duplex Digital Signal  input

RS-485 Half Duplex Digital Signal  output

 

    Overview

    The communication signal of PHD-11TC-11 is input into the isolated safety barrier, which can realize the two-way communication of  RS-485 Half Duplex digital signal in the dangerous area and the safe area. The circuit provides power distribution for on-site instruments. The voltage value can be switched through the top dial switch. The specific operation method is shown in the chart below.
    This product needs independent power supply, and the power supply, input and output are isolated.

    Specifications

    Input in harzadous area
    Input signal RS-485 Half Duplex Digital Signal
    Safety side output:
    Output signal RS-485 Half Duplex Digital Signal
    Transmission delay  ≤10μs
    Transmission rate  ≤1.2kbps~56kbps
    Supply voltage 20-35VDC
    Power consumption ≤150mA (24V power supply, 6V/100mA power distribution.)
    LED indicator  Green: Power indicator
    Yellow: Signal transmission from safety zone to harzadous zone
    Red: Signal transmission from  harzadous zone to safety zone
    Receiving and transmitting switching time  ≥20ms
    Temperature parameters Working temperature: -20℃~+60℃
    storage temperature:-40℃~+80℃
    Relative humidity 10%~95% RH no condensation
    Dielectric strength Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min);
    between power supply and non-intrinsically safe terminal (≥ 1500VAC/min)
    Insulation resistance ≥100MΩ (between input/output/power supply)
    Electromagnetic compatibility According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
    MTBF 100000h
    Wire requirements Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V
    Applicable field equipments Communication interface device with RS-485 Half Duplex Digital Signal
    Installation place Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC
    Intrinsically safe certification
    Explosion proof mark [Ex ia Ga]lIC [Ex ia Da]lllC
    Explosion-proof standard GB/T3836.1-2021  GB/T3836.4-2021
    Terminals 2-3 Um:250V AC/DC Uo=17.8V DC lo=260mA
    Po=1.2W Co=0.22μF Lo=0.25mH
    Terminals 5-6 Um:250V AC/DC Uo=7.7V DC lo=80mA
    Po=0.15W Co=6.9μF Lo=5mH
    Certification body CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)

     

    Dimension

    PHD-11TD-33M(1).jpg

    Schematic Diagram

    PHD-11TD-33M(2).jpg

    Note:

    1. The power rail function is an optional function, and users need to specify the power supply method when placing an order

    The selection of power rail connectors can refer to page 89 of the "Annex"