Get Instant Quote
Leave Your Message
PHD-11TN-11 / PHD-22TN-1111

FDI

Products Categories
Featured Products

PHD-11TN-11 / PHD-22TN-1111

Flame and smoke detector input isolation safety barrier

0~40mA input, 0~40mA putput

PHD-11TN-11 1 input 1 output

PHD-22TN-1111 2 inputs 2 outputs

    Overview

    The isolated safety barriers with flame and smoke detectors input signals, which can provide isolation power for flame detectors in hazardous areas. The flame detector generates 0-40mA signals from the hazardous area and transmits them to the safe area, playing a smoke alarm role. This product adopts output loop power supply and is suitable for DCS/PLC systems with loop power supply.
    This product does not require independent power supply, and the input and output terminals are isolated.

     

    Specifications

    Input in harzadous area
    Input signal 0~40mA
    Distribution voltage Uo≥Ui-(280+RL)I-6,Ui≤24V Uo≥18-(280+RL)l,Ui>24V
    Short circuit current ≤65mA (when powered by 24V)
    Safety side output:
    Output signal 0~40mA
    Signal power supply 20-35VDC
    LED indicator  Green: power indication
    Transmission accuracy <0.2F.S
    Response time  2ms reaches 90% of the final value.
    Temperature drift 0.01%F.S/℃
    Temperature parameters Working temperature: -20℃~+60℃
    storage temperature:-40℃~+80℃
    Relative humidity 10%~95% RH no condensation
    Dielectric strength Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min);
    between power supply and non-intrinsically safe terminal (≥ 1500VAC/min)
    Insulation resistance ≥100MΩ (between input/output/power supply)
    Electromagnetic compatibility According to IEC 61326-1(GB/T 18268), IEC 61326-3-1
    MTBF 100000h
    Wire requirements Horizontal cutting surface ≥ 0.5mm2; Insulation strength ≥ 500V
    Applicable field equipments Flame and smoke detector
    Installation place Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC
    Intrinsically safe certification
    Explosion proof mark [Ex ia Ga]lIC [Ex ia Da]lllC
    Explosion-proof standard GB/T3836.1-2021  GB/T3836.4-2021
    Terminals5-6, 2-3 Um:250V AC/DC Uo=25.2V DC lo=93mA
    Po=586mW Co=0.083μF Lo=4.2mH
    Certification body CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)

     

    Dimension

    PHD-11TN-11.jpg

    Schematic diagram

    PHD-11TN-11(1).jpg

    Note:

    PHD-11TN-11 does not include input 2 and output 2 parts