Get Instant Quote
Leave Your Message
PHD-11TT-88

Temperature input

Products Categories
Featured Products

PHD-11TT-88

Isolated Safety Barrier 
PHD-11TT-88

TC input/ TC 1:1 output
1 input 1 output

    Overview

    Isolated safety barrier at detection side: PHD-11TT-88, thermocouple signal input, single input and single output.
    The isolated safety barrier can realize the transmission of thermocouple signals (-5-60mV) from dangerous areas in proportion 1:1 to the safe area, and thermocouples can be K, S, E, J, B, T, R, N types. 
    When ordering, please indicate the specific parameters 
    *Bus terminal power supply, please see appendix for details.

     

    Specifications

     

    Supply voltage

    20~35VDC, power consumption<0.8W

    Input signal

    K, S, E, J, B, T, R, N, TC Signals

    Output signal

    TC 1:1

    Signal and measurement range

    Signal range: corresponding to the measuring range of TC -5~60mV

    Measurement range: When make an order, the user shall make the configuration by himself, which shall be indicated in the tail number or extra explained.

    Channel number of input and output

    1 input 1 output

    Output accuracy

    0.1%F.S (Typical value: 0.05%F.S)

    Temperature drift

    0.005%F.S/℃

    Temperature parameters

    Working temperature: -20℃~+60℃, storage temperature:-40℃~+80℃

    Relative humidity

    10%~95% RH no condensation

    Dielectric strength

    Between intrinsically safe side and non-intrinsically safe side (≥ 3000VAC/min); between power supply and non-intrinsically safe terminal (≥ 1500VAC/min)

    Insulation resistance

    ≥100MΩ (between input/output/power supply)

    External dimensions

    Thickness 12.5mm x width 108mm x high 118mm

    Electromagnetic compatibility

    According to IEC 61326-1(GB/T 18268), IEC 61326-3-1

    Explosion-proof mark

    [Exia Ga]IIC

    Certification Body

    CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)

    Certified parameters (between terminals 3-4)

     

    Installation site Requirements

    It can be connected with instruments in 0 zone with ⅡA, ⅡB, ⅡC dangerous gas

    MTBF

    ≤100000h

     

    Wiring diagram

    phd-11-xhe

     

    Terminal assignments and dimensions

    Terminal

    Terminal assignments

    9

    Power supply +

    20~35VDC

    10

    Power supply -

    3

    Input+

    TC(mV)

    4

    Input-

    5

    Output+

    TC(mV)

    6

    Output-

     

    phd-11-yk0

    Product Display

    PHD-11TF-28ysk
    PHD-11TF-288tl