PHG-11SZ series

RTD signal input/DC signal output

1 input 1 output

    Overview

    RTD signal input, DC signal output, single input and signal output.

    Intelligently programmable, the actual measuring range of RTD can be set by computer.

    In the "Common models and parameters" the number "8" means "customizable".

     

    Specifications

    RTD excitation current

    800uA

    Load capacity

    Current type load resistance≤500Ω, voltage type load current<5mA

    Output accuracy

    0.1%F.S

    Temperature drift

    0.005% F.S/

    Temperature parameters Working temperature

     -20~+60, storage temperature: -40~+80

    Relative humidity

    10%~95% RH no condensation

    Insulation resistance

    Between input and output, between input, output and power supply≥100MΩ (500VDC)

    Dielectric strength

    Between input and output, between input, output and power supply≥2000VAC/min

    Electromagnetic compatibility

    GB/T 18268IEC 61326-1

    Power supply

    24VDC±10%

    Response time

     100ms

    Power consumption

    Current output<0.8W, voltage output<0.6W

    MTBF

    8000hour

     

    Dimensions

     

    phg-11ss3k

    Schematic diagram and terminal assignments

    phg-11sihq

     

    Terminal

     

    Terminal assignments

    1

    Power supply +

    24VDC±10%

    2

    Power supply -

     

    2-wire

    3-wire

     

    5

    Input+

     Input+

     

     

    RTD signal

    6

    Input-

     Input-

    7

    Short connected with terminal 6

     Input-

    3

    Output+

     

    DC signal

    4

    Output-

     

    Model definition

    phg-11suhj 

     Parameters definition

     

    Code

     

    Output parameters

    1

    420mA

    2

    020mA

    3

    05V

    4

    010V

    5

    15V

    6

    1:1

    7

    ±10V

    8

    Customiza

     

     Parameters definition

     

    Code

     

    RTD model

     

    Measurement range

     

    Minimum range

     

    Conversion accuracy

    1

    G53

    -50150℃

    20

    0.2℃/0.1%

    2

    Cu50

    -50150℃

    20

    0.2℃/0.1%

    4

    Pt100

    -200850℃

    20

    0.2℃/0.1%

    6

    Pt1000

    -200850℃

    20

    0.2℃/0.1%

    7

    Ni1000

    -60250℃

    20

    0.2℃/0.1%

     

    Common models and parameters

     

    Model

     

    Channel numbers

     

    Input

     

    Output

     

    Power supply condition

     

    PHG-11SZ-41

    1 input 1 output

    Pt100(-200850℃)

    420mA

    24VDC

    PHG-11SZ-42

    1 input 1 output

    Pt100(-200850℃)

    020mA

    24VDC

    PHG-11SZ-43

    1 input 1 output

    Pt100(-200850℃)

    05V

    24VDC

    PHG-11SZ-44

    1 input 1 output

    Pt100(-200850℃)

    010V

    24VDC

    PHG-11SZ-45

    1 input 1 output

    Pt100(-200850℃)

    15V

    24VDC

    PHG-11SZ-47

    1 input 1 output

    Pt100(-200850℃)

    ±10V

    24VDC

    PHG-11SZ-11

    1 input 1 output

    G53(-50150℃)

    420mA

    24VDC

    PHG-11SZ-21

    1 input 1 output

    Cu50(-50150℃)

    420mA

    24VDC

    PHG-11SZ-61

    1 input 1 output

    Pt1000(-200850℃)

    420mA

    24VDC

    PHG-11SZ-71

    1 input 1 output

    Ni1000(-60250℃)

    420mA

    24VDC

    PHG-11SZ-88

    1 input 1 output

    Customizable

    Customizable

    24VDC

     