- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
PHG-11TT Series
Overview
TC signal input, DC signal output, single input and signal output.
Intelligently programmable, the actual measuring range of TC can be set by computer.
In the "Common models and parameters" the number "8" means "customizable".
Specifications
Input resistance |
≥100KΩ |
Load capacity |
Current type load resistance≤500Ω, voltage type load current<5mA |
Output accuracy |
0.1%F.S |
Temperature drift |
0.005% F.S/℃ |
Temperature parameters |
Working temperature: -20℃~+60℃, storage temperature: -40℃~+80℃ |
Cold junction compensation |
±1℃ (compensation range -20℃~+60℃) |
Relative humidity |
10%~95% RH no condensation |
Insulation resistance |
Between input and output, between input, output and power supply≥100MΩ (500VDC) |
Dielectric strength |
Between input and output, between input, output and power supply≥2000VAC/min |
Electromagnetic compatibility |
GB/T 18268(IEC 61326-1) |
Power supply |
24VDC±10% |
Response time |
<100ms |
Power consumption |
Current output<0.8W, voltage output<0.6W |
MTBF |
80000(h) |
Dimensions
Schematic diagram and terminal assignments
Terminal |
Terminal assignments |
|
9 |
Power supply + |
24VDC±10% |
10 |
Power supply - |
|
3 |
Input+ |
TC signal |
4 |
nput- |
|
5 |
Output+ |
DC signal |
6 |
Output- |
Model definition
Parameters definition |
||||
Code |
TC model |
Measurement range |
Minimum range |
Conversion accuracy |
1 |
K |
-200~1370℃ |
50℃ |
0.5℃/0.1% |
2 |
S |
-50~1760℃ |
500℃ |
1.5℃/0.1% |
3 |
E |
-140~1000℃ |
50℃ |
0.5℃/0.1% |
4 |
J |
-160~1200℃ |
50℃ |
0.5℃/0.1% |
5 |
B |
250~1800℃ |
500℃ |
1.5℃/0.1% |
6 |
T |
-200~400℃ |
50℃ |
0.5℃/0.1% |
7 |
R |
-50~1760℃ |
500℃ |
1.5℃/0.1% |
8 |
N |
-200~1300℃ |
50℃ |
0.5℃/0.1% |
Common models and parameters
Model |
Channel numbers |
Input |
Output |
Power supply condition |
PHG-11TT-11 |
1 input 1 output |
K(-200~1370℃) |
4~20mA |
24VDC |
PHG-11TT-13 |
1 input 1 output |
K(-200~1370℃) |
0~5V |
24VDC |
PHG-11TT-14 |
1 input 1 output |
K(-200~1370℃) |
0~10V |
24VDC |
PHG-11TT-15 |
1 input 1 output |
K(-200~1370℃) |
1~5V |
24VDC |
PHG-11TT-16 |
1 input 1 output |
K(-200~1370℃) |
0~75mV |
24VDC |
PHG-11TT-17 |
1 input 1 output |
K(-200~1370℃) |
±10V |
24VDC |
PHG-11TT-21 |
1 input 1 output |
S(-50~1760℃) |
4~20mA |
24VDC |
PHG-11TT-31 |
1 input 1 output |
E(-140~1000℃) |
4~20mA |
24VDC |
PHG-11TT-41 |
1 input 1 output |
J(-160~1200℃) |
4~20mA |
24VDC |
PHG-11TT-51 |
1 input 1 output |
B(250~1800℃) |
4~20mA |
24VDC |
PHG-11TT-61 |
1 input 1 output |
T(-200~400℃) |
4~20mA |
24VDC |
PHG-11TT-71 |
1 input 1 output |
R(-50~1760℃) |
4~20mA |
24VDC |
PHG-11TT-81 |
1 input 1 output |
N(-200~1300℃) |
4~20mA |
24VDC |
PHG-11TT-18 |
1 input 1 output |
K(-200~1370℃) |
Customizable |
24VDC |
Note: When make an order, please indicate the actual measured temperature range after the product model.