    Product overview

    12.4mm ultra-thin design;

    Surge protection modules are hot pluggable, no desconnection after unplugging;

    Surge protective module can be individually detected, convenient to maintain;

    Suitable for TC, RTD, CAN, RS485, RS422 and other floating signals circuit ;

    Earthing through DIN35 metal rail.

    Product specification

    Technical data Two-wire Three-wire Four-wire
    RatedoperatingUvnoltage Un 5V 5V 5V
    MaximumoperUatcing voltage Uc 6V 6V 6V
    Nominal operating current IL 1A 1A 1A
    Nominal discharge current In (8 / 20μs) 10kA 10kA 10kA
    The maximum discharge current (8 / 20μs) 20kA 20kA 20kA
    Lightning surge current limp (10 / 350μs) 2.5kA 2.5kA 2.5kA
    Total lightning surge current (10 / 350μs) 5kA 7.5kA 10kA
    Protection voltage Up (8 / 20μs) line-to-line / line to ground 40V/600V 40V/600V 40V/600V
    Protection voltage Up (1KV / μs) line to line / line to ground 20V/600V 20V/600V 20V/600V
    Bandwidth (-0.5dB) 10MHz 10MHz 10MHz
    Response time 1ns 1ns 1ns
    Series resistance (per line)
    Leakage current <10µA <10µA <10µA
    Degrees of protection provided by enclosure (in line with IEC 60529) IP 20 IP 20 IP 20
    Housing material / Flame retardant grade (the UL94) PC/V0 PC/V0 PC/V0
    Test standard GB/T 18802.21 / IEC61643-21 GB/T 18802.21 / IEC61643-21 GB/T 18802.21 / IEC61643-21
    Working temperature range -40 ℃ ~ +80 ℃ -40 ℃ ~ +80 ℃ -40 ℃ ~ +80 ℃

     

    Diagram

    信号5V.png

    Dimension drawings

    信号5V-1.png

    Schematic diagram

    信号5V-2.png