- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
PHD-11TT-*1
TC input/ 4-20mA output (configurable) 1 input 1 output
Overview
^ Isolated detection end safety barrier: PHD-11TT-*1, thermocouple signal input, single input and single output, the safety barrier can realize the conversion of thermocouple signal input in dangerous area into 4-20mA signal output and transmit it to safe area. The circuit has one thermocouple input and one DC signal 4-20mA output.
^ The output 4-20mA signal can be intelligently configured, and the actual measuring range can be set by computer.
^ PHD-11TT-*1, "*" indicates the input type of thermocouple, please use code to indicate it.
This product needs an external power supply of 20~35VDC
PH-200 Online Dew Point Analyzer
1.The signal control unit and the sampling measurement unit are installed separately to overcome the dust,high temperature and acid corrosion problems of high temperature smoke,so that it can measure the moisture in high temperature stably online for a long time.
2.Adopt the new generation foreign sensors,the measurement accuracy is much more higher.
3.Equipped with automatic calibration function, which can greatly reduce the deviation that may occur in the dry end of the dew point measurement.
Equipped with sensor heating function,which can improve the performance of sensor in high humidity and freezing environments without interfering its measured output value
PH6403-3A1B Intelligent safety relay
Overview
PH6403-3A1B is a safety relay control module suitable for two wire safety mats inputs, with 3 normally open (NO) safety output contacts and 1 normally closed (NC) auxiliary output contact for safety relays. It supports manual or automatic reset and has a reset button monitoring function.
PHG-12TE series
DC signal input with provided power/DC signal output
1 input 2 outputs
Overview
DC signal input with provided power, single input, dual DC signal output.
The parameters of output can be customized according to the requirements of
customers.
Supply power 24 VDC.
In the "Common models and parameters" the number "8" means "customizable".
PHG-12TZ series
RTD signal input/DC signal output
1 input 2 outputs
RTD signal input, DC signal output, single input and dual output.
Intelligently programmable, the actual measuring range of RTD can be set by computer. In the "Common models and parameters" the number "8" means "customizable".
PHG-12TT Series
TC signal input/DC signal output
1 input 2 outputs
Overview
TC signal input, DC signal output, single input and dual outputs.
Intelligently programmable, the actual measuring range of TC can be set by computer. In the "Common models and parameters" the number "8" means "customizable".
PHL-TX24-P3-*-EX Field Instrument Surge Pr...
Product overview
Intrinsically safe explosion-proof certification suitable for protection of 2-wire, 3-wire and 4-wire transmitter, TC, RTD, RS485, RS232, RS422, flow meter, electromagnetic valve etc.
Network Signal Surge Protective Devices
Standard BNC coaxial interface is used for lightning protection of SD coaxial video surveillance system.
PHL-T5-L2-EX
Intrinsically Safe Surge Protective Devices with 5V Voltage System
PH-TY series RS422 bus data optical transc...
Product overview
PH-Co series product is an industrial ControlNet data optical transceiver, which supports rate 5Mbps, standard BNC connector compatible with ControlNet data interface, support single optical port/dual optical port chain network and ControlNet protocol. 35mmDIN, DC 9-30V power supply. PH-Co supports two cascadable upstream and downstream optical fiber interfaces, one data interface, ZD-Co supports one optical fiber interface and one data interface.
PHD-22HZ-*1*1
Overview
PHD-22HZ-*1*1, RTD signal input, dual input, and dual output constitute the isolated safety barrier.
The isolated safety barrier has the ability to transmit the 4/20mA signal output that is produced from the RTD input signal in the hazardous area to the safe area. The circuit has two RTD signal inputs and a DC double output.
The 4–20 mA output signal can be set up wisely. A computer can be used to set the real range of RTD.
PHD-22HZ-*1*1, where "*" denotes the RTD input type; please use the code to specify.
This product requires a separate power source.
Input signal types and measurement range
PHD-12TD-211
PHD-12TD-211
Two or three-wire transmitter or current source input /4~20mA output 1 input 2 output
Overview
PHD-12TD-211 is an isolated detection end safety barrier designed specifically for analog input and output.