Isolator Conversion motherboard PHFD-16AIO-D
Number of channels: 16 channels (dual channels)
Signal type: Dual line analog (temperature, voltage/current) input/analog output, three terminal isolation
Supporting isolation barrier: MTL5500 series dual channel analog safety barrier, P+F、 Pinghe simulation guide rail grid (12.8/16/18mm)
Loop current: LED current indication online test hole
Installation form: M4.8 self tapping or M4 screw fixation
Supporting card components:
S7-300PLC: 6ES7 331-1KF02 \ 7KF02 \ 7NF00 \ 7NF10332-5HF00 \ 650-8AK70, etc.
This product does not support the 7KF02 loop power supply mode (range card D).
Number of channels: 16 channels (dual channels)
Signal type: Dual line analog (temperature, voltage/current) input/analog output, three terminal isolation
Supporting isolation barrier: Pinghe simulation guide rail grid (12.8/16/18mm)
Loop current: LED current indication online test hole
Installation form: M4.8 self tapping or M4 screw fixation
Supporting card components:
S7-300PLC: 6ES7 331-1KF02 \ 7KF02 \ 7NF00 \ 7NF10332-5HF00 \ 650-8AK70, etc.
This product does not support the 7KF02 loop power supply mode (range card D).
Power supply and DB port power settings:
This product is designed for redundant power supply and comes with a power loss alarm output
DB1 port contains a 4-core power cord for supplying power to the PLC module. These power supplies are controlled by short-circuit caps set by the power output, with each short-circuit cap corresponding to a wire, as shown in the upper right figure. Before power transmission, settings should be made as needed.
Special note:
1. The brightness of the circuit LED can roughly indicate the magnitude of the circuit current;
2. Using a multimeter to short-circuit the current range of this circuit test hole can accurately measure the inner current without affecting the circuit operation;
When the circuit LED fails and opens, a spare LED can be inserted into the test hole for repair;
Parameter
Order model |
PHFD-16AIO-D |
describe |
Analog input-output isolation conversion board |
Technical parameters | |
Channel |
sixteen |
Number of isolation barriers |
8 dual channels |
Internal power supply voltage |
22-30VDC redundant power supply |
Power loss alarm output |
normally closed |
Internal circuit current indication |
LED brightness, non rewiring test hole |
Maximum current of on-site side channel |
25mA |
Internal connection type |
D-SUB37PF + HART |
On site side connection type |
screw |
Terminal crimping specifications |
0.3~2.5(mm2) |
signal type |
2-wire transmitter, four wire system signal, temperature signal, current output |
Isolator output signal |
4-20mA |
operation temperature |
-30˚C~+55˚C |
storage temperature |
-40˚C~+70˚C |
Dimensions (length x width x height) |
168X112*60mm |
Installation size |
M4.8 self tapping or M4 screw 159mm |
attachment | |
Power insurance |
Fang Insurance 2A |
Matching Cable | |
Order model |
FL-37D-23A40-Y-Z-Xm |