English
English Russian Chinese Simplified Chinese Traditional French German Portuguese Spanish Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Get Instant Quote
Leave Your Message
PHC-11TF-34 PHC-22TF-3434
Digital Output
Products Categories
Featured Products

PHC-11TF-34 PHC-22TF-3434

PHC-11TF-34       1 input 1 output

PHC-22TF-3434   2 inputs  2 outputs

Input: Contact-controlled DC voltage
Output: Switch output driving 12V (45mA)

    Overview

    The 12V/45mA switch output isolating safety barrier transmits power from the safe area to the hazardous area through contact switch control, driving intrinsically safe field devices such as solenoid valves and audible/visual alarms. The input side in the safe area is connected to the power supply via contacts.

     

    PHC-11TF-34 PHC-22TF-3434

     


    Specifications

     

    Input in safe area

     

    Input signal

    Contact-controlled DC voltage

    Controlled power supply

    20~35VDC

    Power consumption

    About 1.8W/channel

    Output in hazardous area

     

    Output signal

    Switch output driving 12V (45mA)

    Open-circuit output voltage

    22V~24V

    Alarm Relay Function

    Set the dip switch K1 (K2) to the "ON" side, and select the alarm function for the channel - (channel 2) circuit
    Short-circuit alarm (SC) when load resistance <50Ω
    Open-circuit alarm (LB) when load resistance >10kΩ

    Alarm Relay Characteristics

     

    Response time

    ≤20ms

    Driving capacity

    250V AC/2A, 30V DC/2A

    Load type

    Resistive load

    Basic Parameters

     

    LED indicators

    CH (channel indicator), ALARM (alarm indicator)

    Temperature parameters

    Working temperature -20℃~+60℃, storage temperature -40℃~+80℃

    Relative humidity

    10%~95% RH no condensation

    Insulation strength

    Between intrinsically safe side and non-intrinsically safe side (≥3000V AC/min)

    Insulation resistance

    ≥100MΩ (between input/output/power supply)

    EMC

    According to IEC 61326-1 (GB/T 18268), IEC 61326-3-1

    Wiring requirements

    Cross-section ≥0.5mm²; insulation strength ≥500V

    Applicable field equipments

    Audible/visual alarms, intrinsically safe solenoid valves

    Installation place

    Installed in a safe zone, it can be connected to intrinsic safety instruments in hazardous areas up to Zone 0, IIC, Zone 20, and IIIC

    Safety Certifications

     

    Explosion-proof marking:

    [Ex ia Ga] IIC [Ex ia Da] IIIC

    Explosion-proof standards:

    GB/T 3836.1-2021, GB/T 3836.4-2021

    Terminals 2-3, 5-6

    250V AC/DC,Uo=25.2V DC,Io=85mA,
    Po=0.535W, Co=0.107μF,  Lo=5mH

    Certification body

    CQST(China National Quality Supervision and Test Centre for Explosion Protected Electrical Products)


    PHC-11TF-34  PHC-22TF-3434

    Note: PHC-11TF-34 does not include input 2 and output 2 parts


    Download_file
    PHD-11TC-33A-23