- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
PHL-TA-100/385/2P PHL-TA-100/385/3P PHL-TA-100/385/4P
Product overview
Using a second level three-phase power surge protector and adopting a common mode protection method of phase to ground (PEN), it is suitable for installation in the LPZl area and At the junction of LPZ2.
Main features
1. Module self-locking function to prevent loss of protection due to loose surfaces;
2.The 'light press' function of module 2 allows for easy insertion and removal of modules for easy replacement,
3 pre connected bases for easy wiring.
Technical parameters
Nominal operating voltage Un
230/400VAC
230/400VAC
230/400VAC
Maximum operating voltage Uc
275VAC
385VAC
440VAC
275VAC
385VAC
440VAC
275VAC
385VAC
440VAC
Protection voltage Up(ln under)
Up<2.0kV
Up<2.4kV
Up<2.6kV
Up<2.0kV
Up<2.4kV
Up<2.6kV
Up<2.0kV
Up<2.4kV
Up<2.6kV
Nominal discharge current In (8/20μs)
60kA
60kA
60kA
Maximum discharge current lmax (8/20μs)
100kA
100kA
100kA
Cross-sectional area of connecting wire
1.5mm²-25mm² flexible wire
1.5mm²-25mm² flexible wire
1.5mm²-25mm² flexible wire
Response time
<25ns
<25ns
<25ns
Enclosure protection degree (according to IEC60529)
IP20
IP20
IP20
Enclosure material/flammable rating
UL94-V0
UL94-V0
UL94-V0
Test standard
GB/T 18802.11/IEC 61643-11
GB/T 18802.11/IEC 61643-11
GB/T 18802.11/IEC 61643-11
Applicable power system
Single phase two wire
Three phase four wire (TN-C system)
Three phase three wire (IT system)
Three phase five wire (TN-S system)
Aging indicator function
Yes (indicating that the window has changed from green to red)
Yes (indicating that the window has changed from green to red)
Yes (indicating that the window has changed from green to red)
Fuse or circuit breaker selection(A)
100、125
100、125
100、125
Aging thermal separation function
Yes
Yes
Yes
Tele-signalization function
Optional
Optional
Optional
RS485 communication
Optional
Optional
Optional
Working temperature range
-40"C~+80"C
-40"C~+80"C
-40"C~+80"C
Installation method
35mm DIN rail
35mm DIN rail
35mm DIN rail
Technical parameters |
|
|
|
|
|
|
|
|
|
Nominal operating voltage Un |
230/400VAC |
230/400VAC |
230/400VAC |
||||||
Maximum operating voltage Uc |
275VAC |
385VAC |
440VAC |
275VAC |
385VAC |
440VAC |
275VAC |
385VAC |
440VAC |
Protection voltage Up(ln under) |
Up<2.0kV |
Up<2.4kV |
Up<2.6kV |
Up<2.0kV |
Up<2.4kV |
Up<2.6kV |
Up<2.0kV |
Up<2.4kV |
Up<2.6kV |
Nominal discharge current In (8/20μs) |
60kA |
60kA |
60kA |
||||||
Maximum discharge current lmax (8/20μs) |
100kA |
100kA |
100kA |
||||||
Cross-sectional area of connecting wire |
1.5mm²-25mm² flexible wire |
1.5mm²-25mm² flexible wire |
1.5mm²-25mm² flexible wire |
||||||
Response time |
<25ns |
<25ns |
<25ns |
||||||
Enclosure protection degree (according to IEC60529) |
IP20 |
IP20 |
IP20 |
||||||
Enclosure material/flammable rating |
UL94-V0 |
UL94-V0 |
UL94-V0 |
||||||
Test standard |
GB/T 18802.11/IEC 61643-11 |
GB/T 18802.11/IEC 61643-11 |
GB/T 18802.11/IEC 61643-11 |
||||||
Applicable power system |
Single phase two wire |
Three phase four wire (TN-C system) |
Three phase five wire (TN-S system) |
||||||
Aging indicator function |
Yes (indicating that the window has changed from green to red) |
Yes (indicating that the window has changed from green to red) |
Yes (indicating that the window has changed from green to red) |
||||||
Fuse or circuit breaker selection(A) |
100、125 |
100、125 |
100、125 |
||||||
Aging thermal separation function |
Yes |
Yes |
Yes |
||||||
Tele-signalization function |
Optional |
Optional |
Optional |
||||||
RS485 communication |
Optional |
Optional |
Optional |
||||||
Working temperature range |
-40"C~+80"C |
-40"C~+80"C |
-40"C~+80"C |
||||||
Installation method |
35mm DIN rail |
35mm DIN rail |
35mm DIN rail |
||||||
Diagram