- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
0102030405
Temperature detection IO module
Product model
PH-LW-2AI-RTD
PH-LW-4AI-RTD
PH-LW-4AI-TC
PH-LW-8AI-TC
Product description
2-channel RTD measuring module
4-channel RTD measuring module
4-channel TC measuring module
8-channel TC measuring module
System bus input current rating
70mA
70mA
70mA
80mA
Sensor type
Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni 200, Ni500, Ni1000, Cu10,Cu50,Cu53,Cu100KTY83-110,
K、E、T、J、B、S、R、N、L and millivolt voltage sensors
KTY83-120,KTY83-121,KTY83-122,KTY83-150,KTY83-151, NTC-5K,NTC-20K,TY84-130,KTY84-150,KTY84-151,
40 fi, 80 fi, 150 fi,300 fi, 500 fi, 1 kfi, 2 kfi, 4 kfi
Resolution/display sensitivity
16bit,0.1℃/bit
Accuracy
±0.3%
The connecting method
2-wire/3-wire
2-wire
Sampling frequency
1.25Hz~7.5Hz
configurable
1.25Hz~5Hz
configurable
1Hz~8Hz
configurable
7200ms~56.25ms
configurable
Channel diagnostic
Upper limit exceeded alarm, lower limit exceeded alarm, disconnection alarm, overflow error
Reverse curcuit protection
Support
Communication error diagnosis
Support
Isolation mode
Optically isolated from the field layer
Dimension
installation parameters
Dimension standard
100mm×12mm×67mm(LWH)
Mounting type
DIN-35 rail
| Product model | PH-LW-2AI-RTD | PH-LW-4AI-RTD | PH-LW-4AI-TC | PH-LW-8AI-TC | |
| Product description | 2-channel RTD measuring module | 4-channel RTD measuring module | 4-channel TC measuring module | 8-channel TC measuring module | |
| System bus input current rating | 70mA | 70mA | 70mA | 80mA | |
| Sensor type | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni 200, Ni500, Ni1000, Cu10,Cu50,Cu53,Cu100KTY83-110, | K、E、T、J、B、S、R、N、L and millivolt voltage sensors | |||
| KTY83-120,KTY83-121,KTY83-122,KTY83-150,KTY83-151, NTC-5K,NTC-20K,TY84-130,KTY84-150,KTY84-151, | |||||
| 40 fi, 80 fi, 150 fi,300 fi, 500 fi, 1 kfi, 2 kfi, 4 kfi | |||||
| Resolution/display sensitivity | 16bit,0.1℃/bit | ||||
| Accuracy | ±0.3% | ||||
| The connecting method | 2-wire/3-wire | 2-wire | |||
| Sampling frequency | 1.25Hz~7.5Hz configurable |
1.25Hz~5Hz configurable |
1Hz~8Hz configurable |
7200ms~56.25ms configurable |
|
| Channel diagnostic | Upper limit exceeded alarm, lower limit exceeded alarm, disconnection alarm, overflow error | ||||
| Reverse curcuit protection | Support | ||||
| Communication error diagnosis | Support | ||||
| Isolation mode | Optically isolated from the field layer | ||||
| Dimension | installation parameters | ||||
| Dimension standard | 100mm×12mm×67mm(LWH) | ||||
| Mounting type | DIN-35 rail | ||||