- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
PHL-TA-160/385/2P PHL-TA-160/385/3P PHL-TA-160/385/4P
Product overview
Using a second level three-phase power surge protector, the common mode protection type of phase to ground (PEN) is suitable for installation at the junction of LPZl zone and LPZ2.
Main features
1. High discharge current, meeting the requirements of T1 testing
2. Using zinc oxide ceramic material, the performance is stable and not affected by environmental changes.
Technical parameters
Nominal operating voltage Un
230/400VAC
230/400VAC
230/400VAC
Maximum operating voltage Uc
275VAC
385VAC
440VAC
275VAC
385VAC
440VAC
275VAC
385VAC
440VAC
Protection voltage Up(ln under)
Up<2.4kV
Up<2.8kV
Up<3kV
Up<2.4kV
Up<2.8kV
Up<3kV
Up<2.4kV
Up<2.8kV
Up<3kV
Nominal discharge current In (8/20μs)
100kA
100kA
100kA
Maximum discharge current lmax (8/20μs)
160kA
160kA
160kA
Cross-sectional area of connecting wire
1.5mm²-25mm² flexible wire
1.5mm²-25mm² flexible wire
1.5mm²-25mm² flexible wire
Response time
<100ns
<100ns
<100ns
Enclosure protection degree (according to IEC60529)
IP20
IP20
IP20
Enclosure material/flammable rating
UL94-V0
UL94-V0
UL94-V0
Test standard
GB/T 18802.11/IEC 61643-11
GB/T 18802.11/IEC 61643-11
GB/T 18802.11/IEC 61643-11
Applicable power system
Single phase two wire
Three phase four wire (TN-C system)
Three phase three wire (IT system)
Three phase five wire (TN-S system)
Fuse or circuit breaker selection(A)
125、160
125、160
125、160
Aging thermal separation function
Yes
Yes
Yes
Tele-signalization function
Optional
Optional
Optional
RS485 communication
Optional
Optional
Optional
Working temperature range
-40"C~+80"C
-40"C~+80"C
-40"C~+80"C
Installation method
35mm DIN rail
35mm DIN rail
35mm DIN rail
Technical parameters |
|
|
|
|
|
|
|
|
|
Nominal operating voltage Un |
230/400VAC |
230/400VAC |
230/400VAC |
||||||
Maximum operating voltage Uc |
275VAC |
385VAC |
440VAC |
275VAC |
385VAC |
440VAC |
275VAC |
385VAC |
440VAC |
Protection voltage Up(ln under) |
Up<2.4kV |
Up<2.8kV |
Up<3kV |
Up<2.4kV |
Up<2.8kV |
Up<3kV |
Up<2.4kV |
Up<2.8kV |
Up<3kV |
Nominal discharge current In (8/20μs) |
100kA |
100kA |
100kA |
||||||
Maximum discharge current lmax (8/20μs) |
160kA |
160kA |
160kA |
||||||
Cross-sectional area of connecting wire |
1.5mm²-25mm² flexible wire |
1.5mm²-25mm² flexible wire |
1.5mm²-25mm² flexible wire |
||||||
Response time |
<100ns |
<100ns |
<100ns |
||||||
Enclosure protection degree (according to IEC60529) |
IP20 |
IP20 |
IP20 |
||||||
Enclosure material/flammable rating |
UL94-V0 |
UL94-V0 |
UL94-V0 |
||||||
Test standard |
GB/T 18802.11/IEC 61643-11 |
GB/T 18802.11/IEC 61643-11 |
GB/T 18802.11/IEC 61643-11 |
||||||
Applicable power system |
Single phase two wire |
Three phase four wire (TN-C system) |
Three phase five wire (TN-S system) |
||||||
Fuse or circuit breaker selection(A) |
125、160 |
125、160 |
125、160 |
||||||
Aging thermal separation function |
Yes |
Yes |
Yes |
||||||
Tele-signalization function |
Optional |
Optional |
Optional |
||||||
RS485 communication |
Optional |
Optional |
Optional |
||||||
Working temperature range |
-40"C~+80"C |
-40"C~+80"C |
-40"C~+80"C |
||||||
Installation method |
35mm DIN rail |
35mm DIN rail |
35mm DIN rail |
||||||
Diagram
Outline dimension diagram
Connection