- Isolated Safety Barriers
- Signal Isolators
- Surge Protective Devices
- Safety Relays
- Isolated Intelligent I/O Modules
- Intelligent Gateways
- Industrial Data Optical Transceivers
- Online Dew Point Analyzers
- Data Acquisition Modules
- HART data converter
- Terminal Board
terminal motherboard PHFS-8AIO-M
PHFS-8AIO-M motherboard with analogue input and output
No. of channels: 8 channels
Signal types: dual wire analogue quantity(temperature, voltage/current) input/analogue output, three terminal isolation
Supporting barriers: PH series single channel analogue barriers
Supporting signal isolators: PH series
Installation form:DIN installation or M5\M6 screw fixation
Online test interface(Use XT801 test instrument, support HART)
Supporting card:
S7-300PLC: 6ES7 331-1KF02\7KF02\7NF00\7NF10,332-5HF00/650-8AK60/650-8BK60
This product can not support 7KF02with loop power supply(measurement range card)
PHD-11HD-21/PHD-11HD-21/PHD-11HZ-*1/PHD-11HT-*1
Common configuration:
Universal input barriers: MTL4541/MTL4641/IMR4641/IMR4641T/IM4045( with provide power, support 2/4 line instruments)
Power supply and DB interface power settings:
This product is with redardunt power supply and with power loss alarm output.
DB1 port contains 2-core power cord, which is used to supply power to PLC module. These power supplies are controlled by the short circuit cap set at the power output. Each short circuit cap corresponds to a wire. Before power transmission, it should be set as required.
Remark:
The Yutong IMR4600 isolator only supports the tester to be inserted into the IM-HART interface to connect HART, and does not support DCS type HART cards
Ordering models:
PHFS-8AIO-M
Description
Analog input and output
Technical specifications
No.of channels
8
No. of barriers
8 single channel
Inside power voltage
24VDC redardunt power
Power loss alarm output
Normal close
Onsite power voltage
24VDC
Onsite channel maxima current
25mA
Inside connection type
D-SUB25PF
Onsite connection type
Screw
Terminal crimping specifications
0.3~2.5(mm2)
Signal type
2-wire transmitter,4-wire signal, temperature signal,current output
Signal isolator output signal
4-20mA
Working temperature
-30˚C~+55˚C
Storage temeperature
-40˚C~+70˚C
Dimension(LxWxH))
152x174x60mm
Installation dimension
M5*4 140.6*101.6mm
ANNEX
Power fuse
Ø5*20 2A
Supporting cable
Ordering models
FL-20D-22A20-Y-Z-Xm
Remark: Y-PLC side interface model Z-cards and signal types X-length
Ordering models: |
PHFS-8AIO-M |
Description |
Analog input and output |
Technical specifications | |
No.of channels |
8 |
No. of barriers |
8 single channel |
Inside power voltage |
24VDC redardunt power |
Power loss alarm output |
Normal close |
Onsite power voltage |
24VDC |
Onsite channel maxima current |
25mA |
Inside connection type |
D-SUB25PF |
Onsite connection type |
Screw |
Terminal crimping specifications |
0.3~2.5(mm2) |
Signal type |
2-wire transmitter,4-wire signal, temperature signal,current output |
Signal isolator output signal |
4-20mA |
Working temperature |
-30˚C~+55˚C |
Storage temeperature |
-40˚C~+70˚C |
Dimension(LxWxH)) |
152x174x60mm |
Installation dimension |
M5*4 140.6*101.6mm |
ANNEX | |
Power fuse |
Ø5*20 2A |
Supporting cable | |
Ordering models |
FL-20D-22A20-Y-Z-Xm |
Remark: Y-PLC side interface model Z-cards and signal types X-length | |